Data
638,021 items of data are available, covering 498,869 participants.
Defined-instances run from 0 to 3, labelled using Instancing
2.
Units of measurement are Kg.
Maximum | 90 |
Decile 9 | 44 |
Decile 8 | 40 |
Decile 7 | 34 |
Decile 6 | 30 |
Median | 28 |
Decile 4 | 24 |
Decile 3 | 22 |
Decile 2 | 20 |
Decile 1 | 16 |
Minimum | 0 |
|
|
- There are 90 distinct values.
- Mean = 29.0624
- Std.dev = 11.2058
- 130 items above graph maximum of 72
|
4 Instances
Instance 0 : Initial assessment visit (2006-2010) at which participants were recruited and consent given
498,529 participants, 498,529 items
Maximum | 89 |
Decile 9 | 46 |
Decile 8 | 40 |
Decile 7 | 36 |
Decile 6 | 32 |
Median | 28 |
Decile 4 | 25 |
Decile 3 | 22 |
Decile 2 | 20 |
Decile 1 | 16 |
Minimum | 0 |
|
|
- There are 86 distinct values.
- Mean = 29.5459
- Std.dev = 11.3277
- 36 items above graph maximum of 76
|
Instance 1 : First repeat assessment visit (2012-13)
20,177 participants, 20,177 items
Maximum | 76 |
Decile 9 | 40 |
Decile 8 | 34 |
Decile 7 | 30 |
Decile 6 | 27 |
Median | 24 |
Decile 4 | 20 |
Decile 3 | 18 |
Decile 2 | 16 |
Decile 1 | 12 |
Minimum | 0 |
|
|
- There are 67 distinct values.
- Mean = 24.9612
- Std.dev = 10.6299
- 4 items above graph maximum of 68
|
Instance 2 : Imaging visit (2014+)
99,042 participants, 99,042 items
Maximum | 90 |
Decile 9 | 42 |
Decile 8 | 38 |
Decile 7 | 32 |
Decile 6 | 30 |
Median | 26 |
Decile 4 | 24 |
Decile 3 | 21 |
Decile 2 | 19 |
Decile 1 | 16 |
Minimum | 0 |
|
|
- There are 84 distinct values.
- Mean = 27.7587
- Std.dev = 10.5547
- 73 items above graph maximum of 68
|
Instance 3 : First repeat imaging visit (2019+)
20,273 participants, 20,273 items
Maximum | 80 |
Decile 9 | 42 |
Decile 8 | 36 |
Decile 7 | 32 |
Decile 6 | 30 |
Median | 26 |
Decile 4 | 24 |
Decile 3 | 21 |
Decile 2 | 19 |
Decile 1 | 16 |
Minimum | 0 |
|
|
- There are 69 distinct values.
- Mean = 27.6229
- Std.dev = 10.3389
- 2 items above graph maximum of 68
|
Notes
Left grip strength.
An issue has been identified with the a small amount of grip strength data (
Field 46 and
Field 47) collected in Cheadle during the first repeat visit in 2013 (Instance 1). We are working on modelling a correction factor for this data. In the meantime, researchers are advised to treat the 2013 grip strength data with caution.
In particular, readings from dynamometer 7336 are lower than expected. The mean error is approximately 2 kg for readings taken in January 2013, gradually increasing to a mean error of 14 kg for readings taken in June 2013.
The dynamometer was recalibrated after June 2013, during scheduled yearly external calibration, and there is no evidence of problems with dynamometer 7336 during instances 0, 2 or 3.
2 Related Data-Fields
Field ID | Description | Relationship |
47 | Hand grip strength (right) | Current Field is the opposite-side complement to Field 47 |
20044 | Reason for skipping grip strength (left) | Field 20044 gives reasons for skipping measurement Current Field |